Page 2 CANopen Industrial Datasheet Version 130305
Technical Data
Electrical Data
Accuracy (T = 0 °C .. +55 °C)
Inclination angle in x and y (1)
typical 1s 10%, 2s 1%, 3s 0,1%
Transceiver according ISO 11898,
galvanically isolated by opto-couplers
Adjustable by rotary switches in connection cap
10 – 30 V DC (absolute limits)
max. 230 mA with 10 V DC, max. 100 mA with 24 V DC
Emitted interference: EN 61000-6-4
Noise immunity: EN 61000-6-3
(1) Supply voltage is applied.
(2) Inclinometers should be connected only to subsequent electronics whose power supplies comply with
EN 50178 (protective low voltage)
Mechanical Data
A=30g; t= 11ms, halfsine (EN 60068-2-27)
10 to 150 Hz, 2,5 mm amplitude, 5g const. Acceleration,
1 Octave /Minute (EN 60068-2-6)
Weight (standard version)
Environmental Conditions
98 % (without liquid state)
IP 67 (connected) (EN 60529)